- Thermostat Atwood Hydro Flame 1H2C Installation & Operation Manual For standard furnaces & a/c systems, two stage furnace digital thermostat (4 pages) Thermostat Atwood HYDRO FLAME 2H2C Installation And Operation Manual Two stage furnace digital thermostat (1 page).
- Atwood 7916-ii Tune-Up Kit. Atwood Furnace Series 7916-II Users Manual. Atwood Hydro Flame 7916-ii Technical Installation Manual MPD 32072. HydroFlame Furnace Exploded Views And Parts List. Tune-Up Kit #1 Obsolete / No Longer Available: Burner Assembly 30268. Single Sense Electrode 37517 (One Wire Goes To Electrode).
- The Atwood 38453 RV Furnace Manual Thermostat is a heat only thermostat. It replaces any 12 volt heat only thermostat, and is compatible for use with the new Atwood Next Generation RV.
- Atwood Hydro Flame Thermostat 38453 Manual
- Atwood Hydro Flame Thermostat Manual
- Atwood Hydro Flame Furnace Thermostat Manual
- Atwood Hydro Flame Thermostat Troubleshooting
- Atwood Hydro Flame Furnace Thermostat Manual
Download Installation and operation manual of Atwood HYDRO FLAME 2H2C Thermostat for Free or View it Online on All-Guides.com.
Brand: Atwood
The Hydro Flame RV Furnace is one of the first units you’ll encounter in your search. This is a lightweight, compact model, weighing in at just 23 pounds with dimensions of 11-3/8″ high, 8-3/8″ wide, and 20-1/2″ deep. Download 4 Atwood Thermostat PDF manuals. User manuals, Atwood Thermostat Operating guides and Service manuals.
Category: Thermostat
Type: Installation and operation manual for Atwood HYDRO FLAME 2H2C
Pages: 1 (0.11 Mb)
ENGLISH, FRANCAIS(et Canada)•Installation •Operation
LITERATURENUMBER
hydro flame
Model 2H2C
Digital Thermostat
9
12VDC
3
2
USED
4
COM
5
COM-
6
HI
7
LOW
8
FURNACE
(OFF) OFF
M
System Switch
Set
Set
Operating Voltage ......................9VDC to 18VDC
................................100mA
..................-40F to +185F
..............+55F to +90F
..+35F to +99F
................................+/- 1F
SCROLL ORDER OF
OPERATION
Scroll Order of Displayed Modes
•
AUFurnace automatically switches between high and low BTU valve and high
and low speed fan when cycling to satisfy set point.
HIFurnace high BTU valve and high speed furnace fan cycle to satisfy set point.
LOFurnace low BTU valve and low speed furnace fan cycle to satisfy set point.
HFFurnace fan runs at high speed to circulate air. Air conditioner fan does not run.
LFFurnace fan runs at low speed to circulate air. Air conditioner fan does not run.
Scroll Order of Displayed Modes
•
Air conditioner automatically switches compressor and high and low speed fan when
•
HIAir conditioner compressor and high speed fan operate to satisfy set point.
LOAir conditioner compressor and low speed fan operate to satisfy set point.
HFAir conditioner fan runs at high speed to circulate air. Furnace fan does not run.
LFAir conditioner fan runs at low speed to circulate air. Furnace fan does not run.
Scroll Order of Displayed Modes
•
HIAir conditioner fan and furnace fan run at high speed to circulate air.
LOAir conditioner fan and furnace fan run at low speed to circulate air.
Scroll Order of Displayed Modes
•
THERMOSTATINSTALLATION
Thermostat is very sensitive. HANDLEWITHCAREATALLTIMES.
Locate thermostat 48˝ to 54˝ above floor on an INTERIORwall.
Pick a dry area where air circulation is good. EXTERIORwall
location must have a 3/4˝ spacer between thermostat and
1. Be sure all electrical power has been disconnected from
the air conditioner, furnace and the power supply.
2. Do not install the thermostat where there are unusual
heating conditions: such as direct sunlight, heat produc-
ing appliances (television, radio, wall lamp, etc.)
3.
ATTACHINGTHEWALLTHERMOSTAT.Separate the thermostat
body from the sub-base by gently squeezing the top and
Atwood Hydro Flame Thermostat 38453 Manual
bottom. Pull wires through access hole in base plate.
Attach thermostat sub-base to the wall at the desired
mounting location. Mount the sub-base to the wall before
THISTHERMOSTATHASBEENDESIGNEDTOOPERATESTANDARDAIRCONDITIONINGUNITSINCONJUNCTIONWITHANEXCALIBUR2-STAGEFURNACE.
Note: Move jumper to
Unit. Discard jumper for
®
Atwood Hydro Flame Thermostat Manual
Related Products for Atwood HYDRO FLAME 2H2C
Atwood Hydro Flame Furnace Thermostat Manual
Related Manuals for Atwood HYDRO FLAME 2H2C
Atwood Hydro Flame Thermostat Troubleshooting
Atwood HYDRO FLAME 2H2C: Frequently viewed Manuals
Atwood Hydro Flame Furnace Thermostat Manual
I have a 2017 Lynx, took it out for the first time this last weekend to test all components and devices and glad to report everything worked well but have one question about the furnace thermostat. The furnace is a Atwood brand I believe a series AFM. The mechanical thermostat is very difficult to turn on. The on/off switch at the top is very hard to click on and off and also the temp slide on the bottom is difficult to determine at what setting it is being set at, you have to sort of slide it back and forth to get it to a comfortable temp. So my question is can the mechanical thermostat be replaced with a digital thermostat? Has anyone replaced one of these with a digital and if so was there a particular type or brand? GEDC1218.jpg